On 29.11 16:28, Adam Aube wrote:
> The only caution about RAID I have seen is that RAID-5 will kill disk
> performance with Squid (due to its usage profile). I don't know if RAID-1
> and RAID-10 are similarly affected.
RAID-1 is disk mirroring, which is safe for the cases one of disks fails.
RAID-0 is stripping that should not be used - squid has better performance
with multiple storages
RAID-5 was already explained, has very poor write performance (and causes
high CPU load)
> For best disk performance you should use several smaller disks and have
> Squid setup a cache dir on each one (no RAID).
agreed.
-- Matus UHLAR - fantomas, [email protected] ; http://www.fantomas.sk/ Warning: I wish NOT to receive e-mail advertising to this address. Varovanie: na tuto adresu chcem NEDOSTAVAT akukolvek reklamnu postu. 42.7 percent of all statistics are made up on the spot.Received on Tue Nov 30 2004 - 07:53:31 MST
This archive was generated by hypermail pre-2.1.9 : Wed Dec 01 2004 - 12:00:02 MST